Cancellation

The IVF cycle will be cancelled if specific criteria occur:
  1. Abnormal screening hormonal levels
  2. Lack of proper stimulation
  3. Failure of estradiol to increase by 20% daily or less than four adequate sized follicles (>20 mm) on ultrasound before retrieval day
  4. Decline in estradiol level the morning after hCG administration (by 20% from the maximum).
  5. LH surge prior to hCG administration plus a drop in estradiol
  6. Lost follicles the day of retrieval
  7. With a flare stimulation, Pattern D: Cycle may be changed to the Luteal Lupron® Protocol, the Microdose Lupron® Protocol, or a GnRH Antagonist Protocol


Return to the Guide
Previous - Questions And Answers